Commit becda742 authored by Stefan Tauner's avatar Stefan Tauner
Browse files

Fix PMC Pm25LV512 and Pm25LV010 probing


Apparently PMC did not understand the purpose of the JEDEC
continuation code. These chips reply to RES (the only supported ID
command) with the prefix-less vendor ID, a device ID, eventually
followed by the continuation byte for the vendor ID.

This fix uses only the first two bytes instead of appending the
continuation code to the device ID. The problem was reported by The
Raven who also tested the fix on a Pm25LV010 (with an imprint of
"Pm25LV010E").

Corresponding to flashrom svn r1806.
Signed-off-by: default avatarStefan Tauner <stefan.tauner@alumni.tuwien.ac.at>
Acked-by: default avatarStefan Tauner <stefan.tauner@alumni.tuwien.ac.at>
parent 0ab1e5d5
......@@ -8595,13 +8595,13 @@ const struct flashchip flashchips[] = {
.vendor = "PMC",
.name = "Pm25LV512(A)",
.bustype = BUS_SPI,
.manufacture_id = PMC_ID,
.manufacture_id = PMC_ID_NOPREFIX,
.model_id = PMC_PM25LV512,
.total_size = 64,
.page_size = 256,
.feature_bits = FEATURE_WRSR_WREN,
.tested = TEST_UNTESTED,
.probe = probe_spi_res3,
.probe = probe_spi_res2, /* The continuation code is transferred as the 3rd byte m( */
.probe_timing = TIMING_ZERO,
.block_erasers =
{
......@@ -8627,13 +8627,13 @@ const struct flashchip flashchips[] = {
.vendor = "PMC",
.name = "Pm25LV010",
.bustype = BUS_SPI,
.manufacture_id = PMC_ID,
.manufacture_id = PMC_ID_NOPREFIX,
.model_id = PMC_PM25LV010,
.total_size = 128,
.page_size = 256,
.feature_bits = FEATURE_WRSR_WREN,
.tested = TEST_UNTESTED,
.probe = probe_spi_res3,
.tested = TEST_OK_PREW,
.probe = probe_spi_res2, /* The continuation code is transferred as the 3rd byte m( */
.probe_timing = TIMING_ZERO,
.block_erasers =
{
......
......@@ -503,7 +503,8 @@
/*
* Programmable Micro Corp is listed in JEP106W in bank 2, so it should
* have a 0x7F continuation code prefix.
* Apparently this name is owned by "Chingis Technology Corporation" http://www.chingistek.com.
* Apparently this name is owned by "Chingis Technology Corporation" http://www.chingistek.com which is now a
* subsidiary of ISSI. They continue to use the PMC manufacturer ID nevertheless.
*/
#define PMC_ID 0x7F9D /* PMC */
#define PMC_ID_NOPREFIX 0x9D /* PMC, missing 0x7F prefix */
......