Add option to disable CRC checking in both FSI master and slave

parent a1eac73c
...@@ -11,6 +11,7 @@ module fsi_master_interface( ...@@ -11,6 +11,7 @@ module fsi_master_interface(
input wire [1:0] data_length, // 0 == 8 bit, 1 == 16 bit, 2 = 32 bit (NOTE: the lower two address bits may be forced if 16 bit / 32 bit transfer length is set) input wire [1:0] data_length, // 0 == 8 bit, 1 == 16 bit, 2 = 32 bit (NOTE: the lower two address bits may be forced if 16 bit / 32 bit transfer length is set)
input wire data_direction, // 0 == read from slave, 1 == write to slave input wire data_direction, // 0 == read from slave, 1 == write to slave
input wire enable_relative_address, input wire enable_relative_address,
input wire enable_crc_protection,
input wire start_cycle, input wire start_cycle,
output wire cycle_complete, output wire cycle_complete,
output wire [2:0] cycle_error, output wire [2:0] cycle_error,
...@@ -126,6 +127,7 @@ module fsi_master_interface( ...@@ -126,6 +127,7 @@ module fsi_master_interface(
reg [31:0] tx_data_reg = 0; reg [31:0] tx_data_reg = 0;
reg [31:0] rx_data_reg = 0; reg [31:0] rx_data_reg = 0;
reg enable_relative_address_reg = 0; reg enable_relative_address_reg = 0;
reg enable_crc_protection_reg = 0;
reg [1:0] enhanced_error_recovery_reg = 0; reg [1:0] enhanced_error_recovery_reg = 0;
reg [8:0] cycle_counter = 0; reg [8:0] cycle_counter = 0;
reg [20:0] last_address = 0; reg [20:0] last_address = 0;
...@@ -229,6 +231,7 @@ module fsi_master_interface( ...@@ -229,6 +231,7 @@ module fsi_master_interface(
endcase endcase
tx_data_reg <= tx_data; tx_data_reg <= tx_data;
enable_relative_address_reg <= enable_relative_address; enable_relative_address_reg <= enable_relative_address;
enable_crc_protection_reg <= enable_crc_protection;
enhanced_error_recovery_reg <= enhanced_error_recovery; enhanced_error_recovery_reg <= enhanced_error_recovery;
slave_error_recovery_state <= 0; slave_error_recovery_state <= 0;
master_error_recovery_state <= 0; master_error_recovery_state <= 0;
...@@ -645,7 +648,7 @@ module fsi_master_interface( ...@@ -645,7 +648,7 @@ module fsi_master_interface(
end end
FSI_TRANSFER_STATE_RX07: begin FSI_TRANSFER_STATE_RX07: begin
crc_protected_bits_receiving = 0; crc_protected_bits_receiving = 0;
if (crc_data != 0) begin if ((crc_data != 0) && enable_crc_protection_reg) begin
// Master received corrupted message from slave // Master received corrupted message from slave
if (((enhanced_error_recovery_reg[1] && ipoll_in_process) if (((enhanced_error_recovery_reg[1] && ipoll_in_process)
|| (enhanced_error_recovery_reg[0] && !ipoll_in_process)) || (enhanced_error_recovery_reg[0] && !ipoll_in_process))
......
...@@ -9,6 +9,7 @@ module fsi_slave_interface( ...@@ -9,6 +9,7 @@ module fsi_slave_interface(
output wire [31:0] rx_data, output wire [31:0] rx_data,
output wire [1:0] data_length, // 0 == 8 bit, 1 == 16 bit, 2 = 32 bit output wire [1:0] data_length, // 0 == 8 bit, 1 == 16 bit, 2 = 32 bit
output wire data_direction, // 0 == read from slave, 1 == write to slave output wire data_direction, // 0 == read from slave, 1 == write to slave
input wire enable_crc_protection,
output wire data_request_strobe, output wire data_request_strobe,
input wire data_ready_strobe, input wire data_ready_strobe,
input wire [1:0] enhanced_error_recovery, // Bit 1 == EER for IPOLL, Bit 0 == EER for all other transmissions input wire [1:0] enhanced_error_recovery, // Bit 1 == EER for IPOLL, Bit 0 == EER for all other transmissions
...@@ -121,6 +122,7 @@ module fsi_slave_interface( ...@@ -121,6 +122,7 @@ module fsi_slave_interface(
reg fsi_data_in_internal_prev = 0; reg fsi_data_in_internal_prev = 0;
reg [20:0] address_rx_reg = 0; reg [20:0] address_rx_reg = 0;
reg [31:0] tx_data_reg = 0; reg [31:0] tx_data_reg = 0;
reg enable_crc_protection_reg = 0;
reg [1:0] enhanced_error_recovery_reg = 0; reg [1:0] enhanced_error_recovery_reg = 0;
reg [8:0] cycle_counter = 0; reg [8:0] cycle_counter = 0;
reg [8:0] break_cycle_counter = 0; reg [8:0] break_cycle_counter = 0;
...@@ -184,6 +186,7 @@ module fsi_slave_interface( ...@@ -184,6 +186,7 @@ module fsi_slave_interface(
// of a received BREAK command, it would result in continual // of a received BREAK command, it would result in continual
// error generation until the end of the command was received! // error generation until the end of the command was received!
if (fsi_data_in_internal && !fsi_data_in_internal_prev) begin if (fsi_data_in_internal && !fsi_data_in_internal_prev) begin
enable_crc_protection_reg <= enable_crc_protection;
enhanced_error_recovery_reg <= enhanced_error_recovery; enhanced_error_recovery_reg <= enhanced_error_recovery;
crc_protected_bits_receiving = 1; crc_protected_bits_receiving = 1;
control_state <= FSI_TRANSFER_STATE_RX01; control_state <= FSI_TRANSFER_STATE_RX01;
...@@ -433,7 +436,7 @@ module fsi_slave_interface( ...@@ -433,7 +436,7 @@ module fsi_slave_interface(
end end
FSI_TRANSFER_STATE_RX10: begin FSI_TRANSFER_STATE_RX10: begin
crc_protected_bits_receiving = 0; crc_protected_bits_receiving = 0;
if (crc_data != 0) begin if ((crc_data != 0) && enable_crc_protection_reg) begin
// Slave received corrupted message from master // Slave received corrupted message from master
if (((enhanced_error_recovery_reg[1] && ipoll_in_process) if (((enhanced_error_recovery_reg[1] && ipoll_in_process)
|| (enhanced_error_recovery_reg[0] && !ipoll_in_process)) || (enhanced_error_recovery_reg[0] && !ipoll_in_process))
......
Markdown is supported